TM
9-2350-238-20-2
2-91. MAINTENANCE OF GAS PARTICULATE FILTER UNIT, AIR PURIFIER ASSEMBLY,
HOUSING PRECLEANED ASSEMBLY, AND GROUND CABLE ASSEMBLY (CONT).
REASSEMBLY
Gas and particulate filters must be
installed only by trained personnel
(FM 3-100). The officer in charge
must specify the necessary pro-
tective
clothing
(TM
10-277).
The
officer must also specify safety
measures and decontamination
procedures that must be perform-
ed before filters are installed
(FM 3-5).
Decontaminate
gas
filter.
Refer
to
1
FM 3-5.
2
Install spring clip (1) to precleaned and
housing assembly (2).
Install
precleaned
and
housing
assembly
3
(2) to vehicle.
4
Install particulate filter (3) in precleaned
and housing assembly (2).
5
Install gas filter (4) in precleaned and hous-
ing
assembly
(2)
with
flush
side
against
particulate
filter
(3).
Install
manifold
assembly
(5)
and
secure
6
with four new Iockwashers (6) and four
machine screws (7).
7
Install four airflow control caps (8) to
M2A2 air purifier assembly (9).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |