INSTALLATION
Make sure MASTER switch is
OFF before repairing electrical
components. Failure to observe
this warning could result in in-
jury or death.
Failure
to
remove
or
disconnect
the batteries before removing or
installing
any
electrical
wiring
harness or lead may result in in-
jury
or
damaged
equipment.
Install shock assembly mount (1), ground
1
cable
assembly
(2),
and
frame
assembly
(3) and secure using four assembled
washer bolts (4).
2
Install two shock mount to boom cylinders
hose clamps (5) and (6). Install gas par-
ticulate filter unit (7) in frame assembly
(3) and secure by engaging holddown
latch (8).
3
Connect M10 hose assembly (9) and M7
hose assembly (10) to gas particulate filter
unit (7).
4
Connect and screw in connector (11) to
gas particulate filter unit (7).
5
Connect ground cable assembly (2) to gas
particulate filter unit (7). Tighten machine
screw (12). Turn MASTER switch to ON.
|