TM
9-2350-238-20-2
DISASSEMBLY
1 Remove four airflow control caps
(1)
from
M2A2 air purifier assembly (2).
2
Remove four machine
screws (3), four
Iockwashers (4), and
manifold assembly
(5).
Gas and particulate filters must be
removed only by trained personnel
(FM 3-100). The officer in charge
must specify the necessary pro-
tective
clothing
(TM
10-277).
The
officer must also specify safety
measures and decontamination
procedures that must be per-
formed before filters are installed
(TM
3-220).
Do not drop or damage filters.
3 Tilt
precleaned
and
housing
assembly
(6)
until gas filter (7) slides out.
4 Tilt precleaned and housing assembly
(6)
until particulate filter (8) slides out.
5 Remove precleaned and housing assembly
(6) from vehicle.
6 Remove
spring
clip
(9)
from
precleaner
and housing assembly (6).
INSPECTION/REPAIR
1 Inspect
for
broken,
damaged,
or
missing
parts.
2 Repair
is
by
replacement
of
authorized
parts
(TM
9-2350-238-24P-2).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |