TM
9-2350-238-20-2
2-14. TYPICAL FEMALE-TYPE PANEL
MOUNTING RECEPTACLE (CONT).
REASSEMBLY
1
Strip cable insulation to depth of solder
wells
of
socket
contacts
(1).
2
Slide nut (2) over cable (3).
3
Slide grommet (4) over cable leads
5).
4
Insert cable leads (5) into solder wells of
socket
contacts
(1)
and
solder.
Push insert (6) into shell assembly (7)
5
from rear until seated. Groove (8) in in-
sert (6) must be alined with guide in
shell assembly (7) to ensure proper fit.
Push socket contacts (1) into insert (6)
6
from rear until seated.
Push
grommet
(4)
down
cable
leads
(5)
7
and
over
solder
wells
of
socket
contacts
(1).
Screw nut (2) onto shell assembly (7).
8
2-15. TYPICAL MALE-TYPE PANEL
MOUNTING RECEPTACLE.
DISASSEMBLEY
1
Unscrew nut (1) from shell assembly (2)
and slide back on cable (3).
2 Push grommet (4) back on cable leads
(5).
3 Drive pin contacts (6) out through rear of
insert (7) with pin extractor.
4
Push
insert
(7)
out
through
rear
of
shell
assembly (2).
5 Unsolder cable leads (5) from pin con-
tacts (6).
|