TM
9-2350-238-20-2
2-13. TYPICAL MALE-TYPE PANEL
MOUNTING RECEPTACLE.
DISASSEMBLY
1 Drive pin contacts (1) out through rear of
insert
(2)
with
pin
extractor.
2 Unsolder
cable
leads
(3)
from
solder
wells on pin contacts (1).
3 Slide
insert
(2)
out
through
rear
of
shell
assembly (4).
REASSEMBLY
Strip cable insulation equal to depth of
1
solder wells of pin contacts (1).
2
Insert cable leads (3) into solder wells of
pin contacts (1) and solder.
Push insert (2) into shell assembly (4)
3
from rear until seated. Groove (5) in in-
sert must be alined with guide in shell
assembly (4) to ensure proper fit.
Push pin contacts (1) into insert (2) from
4
rear until seated.
2-14. TYPICAL FEMALE-TYPE
PANEL
MOUNTING RECEPTACLE.
DISASSEMBLY
1 Unscrew
nut
(1)
from
shell
assembly
(2)
and slide back on cable (3).
2 Slide
grommet
(4)
back
on
cable
leads
(5).
3 Drive socket contacts (6) out through
front of insert (7) with pin extractor.
l e a d -f r o m s o c k e t c o n t a c t s ( 6 ) .
4 Unsolder
5 P u s h i n s e r t ( 7 ) out through rear of shell
assembly (2).
|