TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 4.
Disconnect lead 401 at turret disconnect. Set MASTER switch ON. Place
red probe in lead 401. Ground black probe. If multimeter indicates about
24 volts, go to step 5. If multimeter indicates no voltage, repair lead 401
between 30A circuit breaker and turret disconnect. Refer to page 2-371.
Set MASTER switch OFF. Connect lead.
Step 5.
Disconnect lead 401 from personnel heater control box. Set MASTER
switch ON. Place red probe in lead 401. Ground black probe. If
multimeter indicates about 24 volts, replace personnel heater control box.
Refer to page 2-1103. If multimeter indicates no voltage, repair lead 401
between turret disconnect and personnel heater control box. Refer to page
2-361
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |