TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Disconnect wiring harness (leads 1, 2, 478, and 506) from voltage
Step 8.
regulator. Check resistance between generator terminal A and ground,
and between generator terminal D and ground. If multimeter indicates 0 to
4 ohms on both terminals, go to step 9. If multimeter indicates more than
4 ohms on one or both terminals, replace generator. Refer to page 2-552.
Connect wiring harness to voltage regulator.
2-144
|