TM 9-2350-238-20-1
2-66. MAINTENANCE OF COOLING SYSTEM FAN TENSlONER AND RELATED PARTS
(CONT).
NOTE
There must be a distance of 0.50 in.
(1.27 cm) between bottom of spring
retainer and top of fan tensioner
coupling plate (1).
1
Loosen hexagon plain nut (2), then tighten
self-locking nut (3) to bring bottom of
spring retainer (4) to top line on instruction
plate (5).
2 Tighten hexagon plain nut (2).
2-67. MAINTENANCE OF GENERATOR AND COOLING AIR INTAKE SYSTEM.
c. Installation
This task covers:
a. Removal
b. Inspection/Repair
INITIAL SETUP
References
Tools and Special Tools
TM 9-2350-238-24P-1
Plier wire twister (item 30, appx G)
Equipment Conditions
Materials/Parts
2-384 Powerplant removed
Duct to bulkhead gasket
Elbow to bulkhead gasket
Gasket
Gasket
Lockwire (item 26, appx C)
Lockwire (item 27, appx C)
Preformed packing
Self-locking nut
Self-locking nut (6)
2-552
|