BLACKOUT LIGHT SWITCH - CONTINUED
INSTALLATION CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Connect battery ground cable (4-444).
2. Check operation (TM 9-2320-270-10).
TASK ENDS HERE
CIRCUIT BREAKERS
This task covers:
b. Installation (page 4-305)
a. Removal (page 4-304)
INITIAL SETUP
Personnel Required
Tools
One
Screwdriver, cross-tip, number 1
Screwdriver, flat-tip, 1/4-inch
Equipment Condition
Wrench, open-end, 3/8-inch
Battery ground cable disconnected
Materials/Parts
Instrument panel open (page 4-244).
Lockwasher, circuit breaker
(two required)
Lockwasher, terminal (two required)
Tag, marking (item 18, appendix C)
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
WARNING
Make sure battery ground cable is disconnected before doing this task. Failure to dis-
connect battery can cause personal injury and damage to electrical system.
NOTE
Steps in this task apply to all circuit breakers in the instrument panel. Number of wires
will vary. STOP LT circuit breaker is shown. Refer to Appendix F Wire List for all circuit
breaker wiring numbers and destinations. Tag wires according to general maintenance
instructions (page 4-1).
4-304