TM9-2320-270-20-1
STARTER - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Close left side of hood and install left hood side panel (TM 9-2320-272-10).
2. Connect battery ground cable (page 4-444).
3. Check operation (TM 9-2320-270-10).
TASK ENDS HERE
MAGNETIC SWITCH
This task covers:
a. Removal (page 4-232)
b. Installation (page 4-234)
INITIAL SETUP
Materials/Parts Continued
Tools
Sand paper, fine grit (item 12, appendix C)
Handle, ratchet, 3/8-inch drive
Tag, marking (item 18, appendix C)
Screwdriver, cross-tip, number 3
Socket, 1/2-inch, 3/8-inch drive
Personnel Required
Wrench, open-end, 1 1/32-inch
One
Materials/Parts
Equipment Condition
Lockwasher, ignition switch and
ground terminal (two required)
Right side of hood open and right side panel
Lockwasher, battery and starter
removed (TM 9-2320-270-10).
terminal (two required)
Battery ground cable disconnected
Lockwasher, magnetic switch to fire-
wall (two required)
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
WARNING
Make sure battery ground cable is disconnected before doing this task. Failure to
disconnect battery ground cable can cause personal injury or damage to electrical
system.
NOTE
Tag wires according to general maintenance instructions (page 4-1).
4-232