TM9-2320-270-20-1
MAGNETIC SWITCH - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REMOVAL - CONTINUED
Using 1 1/32-inch wrench, unscrew and
Nut (2)
7. Ground terminal (1))
take off.
a. Take off.
Lockwasher (3) and
8.
b. Get rid of Iockwasher (3).
ground wire (4)
a. Using screwdriver, unscrew and take
Two screws (6) and
9. Magnetic switch (5)
out.
Iockwasher (7)
b. Get rid of Iockwashers (7).
Take out.
Magnetic switch (5)
10. Firewall (8)
and ground wire (4)
lNSTALIATION
Using fine sandpaper, sand to bare metal
Firewall (8)
11.
an area about 1/8 inch (3.17 millimeters)
around hole.
Put in position.
Magnetic switch (5)
12.
and ground wire (4)
Using screwdriver, screw in and tighten.
Two screws (6) and
13. Magnetic switch (5)
new Iockwasher (7)
Put on.
Ground wire (4) and
14. Ground terminal (1)
new Iockwasher (3)
Screw on and, using 1 1/32-inch wrench,
Nut (2)
15.
tighten.