TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
30. INSTRUMENT PANEL GAGE LIGHT DOES NOT WORK CONTINUED.
Using multimeter set at 30 vdc, put red probe on circuit breaker terminal (1) and
Step 7.
black probe on panel (2).
If meter reads no voltage, do step 9 under BOTH HEADLIGHTS DO NOT
WORK (page 3-48).
Using multimeter set at 30 vdc, put red probe on circuit breaker terminal (3) and
Step 8.
black probe on panel (2).
a. If meter reads no voltage, close instrument panel (page 4-244), put
headlight switch in OFF position and notify direct support
maintenance.
b. If meter reads voltage, put headlight switch in OFF position and
replace horn circuit breaker (page 4-304).
c. If instrument panel gage lights still do not work, notify direct support
maintenance.
TA239668