TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
31. WORK LIGHT DOES NOT WORK.
NOTE
If both lights do not work, go to step 3.
Remove work light lamp (1) (page 4-332). Using multi meter set at RX1, put red
Step 1.
probe on one lamp terminal (2) and black probe on other terminal (3).
If meter does not show zero, replace lamp (page 4-332).
Go to ground wire (4). Using multimeter set for RX1 continuity check, put red
Step 2.
probe on wire end (5) and black probe to good ground (6).
If meter does not show zero, install work light lamp (page 4-332) and
notify direct support maintenance.
TA239669
3-81
|