TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
31. WORK LIGHT DOES NOT WORK CONTINUED.
Install work light lamp (page 4-332). Go to instrument panel. Put dome light
Step 3.
switch (1) in ON position, and blackout switch (2) in LIGHTS position.
If dome light does not work, do BOTH HEADLIGHTS DO NOT WORK (page
3-48), steps 6 thru 9.
Put dome light switch (1) in OFF position, open instrument panel (page 4-244)
Step 4.
and go to work light switch (3). Using multimeter set at 30 vdc, put red probe on
wire no. 040 (4) from circuit breaker to switch, and black probe to good ground.
If meter reads no voltage, close instrument panel (page 4-244) and
notify direct support maintenance.
TA239670
3-82