TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 5.
Using muitimeter set at 30 vdc, put red probe on light control rheostat terminal
(4) and black probe on panel (5).
a. If meter reads no voltage, put headlight switch in OFF position and
replace light control rheostat (page 4-286).
b. If meter reads voltage, close instrument panel (page 4-244), put
headlight switch in OFF position and notify direct support
maintenance.
Using multimeter set at 30 vdc, put red probe on headlight switch terminal (6)
Step 6.
and black probe on panel (5).
a. If meter reads no voltage, close instrument panel (page 4-244), put
headlight switch in OFF position and notify direct support
maintenance.
b. If meter reads voltage, put light switch in OFF position and replace
headlight switch (page 4-288).
TA239667
3-79
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |