TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
30. INSTRUMENT PANEL GAGE LIGHT DOES NOT WORK CONTINUED.
Put headlight switch (1) to ON position. Put blackout switch (2) in LIGHTS
Step 2.
position. Turn light control rheostat (3) clockwise as far as possible. Open
instrument panel (page 4-244). Using multimeter set at 30 vdc, put red probe on
rheostat terminal (4) and black probe on panel (5).
If meter reads voltage, close instrument panel (page 4-244), put head-
light switch in OFF position and notify direct support maintenance.
Push horn button (6).
Step 3.
If horn does not sound, go to step 7.
Using voltmeter set at 30 vdc, put red probe on headlight switch terminal (7) and
Step 4.
black probe on panel (5).
If meter reads no voltage, go to step 6.
TA239666