TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. ENGINE FAILS TO CRANK CONTINUED.
Open right side of hood and remove right side panel (TM 9-2320-270-10).
Step 11.
Have assistant turn ignition key to START position. Using multimeter set at
30 vdc, put red probe on magnetic switch power terminal (1) and black probe
on bulkhead (2).
If meter reads no voltage, close instrument panel (page 4-244), install
left and right side panels, close right side of hood (TM 9-2320-270-
10), and notify direct support maintenance.
Using multimeter set at 30 vdc, put red probe on magnetic switch terminal (3)
Step 12.
and black probe on bulkhead (2).
If meter reads no voltage, replace switch (page 4-232), close
instrument panel (page 4-244), install right and left side panels and
close right side of hood (TM 9-2320-270-10).
3-10
|