TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 9.
Using multimeter set at 30 vdc, put red probe on one side of instrument panel
ignition switch circuit breaker terminal (4) and black probe on panel (5).
If meter reads no voltage, turn key to OFF position, close instrument
panel (page 4-244), install left side panel, close left side of hood
(TM 9-2320-270-10), and notify direct support maintenance.
Step 10.
Using multimeter set at 30 vdc, put red probe on one side of instrument
panel ignition switch circuit breaker terminal (6) and black probe on panel (5).
If meter reads no voltage, turn key to OFF position, replace circuit
breaker (page 4-304), install left side panel and close left side of
hood (TM 9-2320-270-10).
3-9
|