TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. ENGINE FAILS TO CRANK CONTINUED.
Open instrument panel (page 4-244). Using multimeter set at 30 vdc, put red
Step 3.
probe on ignition switch BATT terminal (1) and black probe on panel (2).
If multimeter reads no voltage, turn key to OFF position, close
instrument panel (page 4-244), install left side panel, close left
side of hood (TM 9-2320-270-10), and notify direct support
maintenance.
Turn key to START position and using multimeter set at 30 vdc, put red probe
Step 4.
on ignition switch START terminal (3), and black probe on panel (4).
If meter reads no voltage, turn key to OFF position, replace ignition
switch (page 4-246), install left side panel, and close left side of
hood (TM 9-2320-270-10).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |