TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 5.
Turn ignition key to ON position. Using multimeter set at 30 vdc, put red probe
on neutral safety switch power terminal (5) and black probe on housing (6).
If meter reads no voltage, turn key to OFF position, close instrument
panel (page 4-244), install left side panel, close left side of
hood (TM 9-2320-270-10), and notify direct support maintenance.
Step 6.
Using multimeter set at 30 vdc, put red probe on neutral safety switch output
terminal (7) and black probe on housing (6).
If meter reads no voltage, turn key to OFF position, replace switch
panel, and close left side of hood (TM 9-2320-270-10).
3-7
|