TM
9-2350-238-20-2
2-16. TYPICAL
FEMALE-TYPE
PLUG
(CONT).
REASSEMBLY
1 Strip cable insulation equal to depth of
solder
wells
of
socket
contacts
(1).
2 Slide nut (2) over cable (3).
3 Slide grommet (4) over cable leads (5).
4 Insert
cable
leads
(5)
into
solder
wells
of
socket
contacts
(1)
and
5 Push insert (6) into shell assembly (7)
from rear until seated. Groove (8) in in-
sert (6) must be alined with guide in
shell assembly (7) to ensure proper fit.
6 Push socket contacts (1) into insert (6)
from rear until seated.
7 Slide
coupling
(9)
onto
shell
assembly
(7).
8 Push
grommet
(4)
down
cable
leads
(5)
and over
solder
wells
of
socket
contacts
(1).
9 Screw
nut
(2)
onto
shell
assembly
(7).
2-17.
TYPICAL
MALE-TYPE
PLUG.
DISASSEMBLY
1 Unscrew nut (1) from shell assembly
(2)
and slide back on cable (3).
2 Slide
grommet
(4)
back
on
cable
leads
(5).
3 Slide coupling (6) off shell assembly (2).
4 Drive pin contacts (7) out through rear of
insert
(8)
with
pin
extractor.
5 Push
insert
(8)
out
through
rear
of
shell
assembly (2).
6 Unsolder cable leads (5) from pin con-
tacts
(7).
|