TM
9-2350-238-20-2
(6)
Utility outlet is non operating when cab flasher headlight and
dome
lights
are
off
and MASTER switch is ON and dome light switches are on.
Make
sure
MASTER
switch
is
OFF
before
repairing
electrical
com-
ponents. Failure to observe this warning could result in injury to
personnel.
Remove lead 38 (1) from circuit breaker (2) output. Place red probe in cir-
Step 1.
cuit breaker receptacle. Ground black probe. Set MASTER switch ON. If
multimeter indicates about 24 volts, repair lead 38 from output side of cir-
cuit breaker, refer to page 2-66. If multimeter indicates no voltage, go to
step 2. Set MASTER switch OFF. Connect lead.
Disconnect
both
leads
38
(1)
from
circuit
breaker
(2).
Connect
multimeter
Step 2.
to receptacles of circuit breaker. If multimeter indicates continuity, repair
lead 38 between circuit breaker and slip ring disconnect, refer to page
2-66. If multimeter indicates
infinity,
replace
circuit
breaker,
refer
to
2-297. Connect leads.
|