TM
9-2350-238-20-2
Disconnect lead 415 (1) from output side of circuit breaker (2). Place red
Step 4.
probe
in
circuit
breaker.
Ground
black
probe.
Set
MASTER
switch
ON.
If
indicates
about
24
volts,
go
to
step
5.
If
indicates
no
voltage, replace circuit breaker, refer to page 2-314. Set MASTER switch
OFF. Connect leads.
Make sure MASTER switch is OFF before repairing electrical com-
ponents. Failure to observe this warning could result in injury to
personnel.
Step 5. Disconnect lead 415 (1) from input side of AIR PURIFIER SWITCH (2).
Place red probe in lead 415. Ground black probe. Set MASTER switch ON.
If multimeter indicates about 24 volts, go to step 6. If multimeter indicates
no voltage, repair lead 415 between AIR PURIFIER SWITCH and circuit
breaker (3), refer to page 2-66. Set MASTER switch OFF. Connect lead.
2-45
|