Click here to make tpub.com your Home Page

Page Title: CAB FILTER lNSTALLATION Cab Air Purifier Circuit. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM
9-2350-238-20-2
2-10.
ELECTRICAL
CIRCUIT
TROUBLESHOOTING
(CONT).
Make
sure
MASTER
switch
is
OFF
before
repairing
electrical
com-
ponents. Failure to observe this warning could result in injury to
personnel.
Disconnect lead 415 (1) from input side of circuit breaker (2). Place red
Step 3.
probe
in
lead
415.
Ground
black
probe.
Set
MASTER
switch
ON.
If
multimeter  indicates  about  24  volts,  go  to  step  4.  If  multimeter  indicates  no
voltage,  repair  lead  415  between  dome  light  connector  and  circuit  breaker,
refer  to  page  2-66.  Set  MASTER  switch  OFF.  Connect  lead.
2-44

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business