TM
9-2350-238-20-2
2-10.
ELECTRICAL
CIRCUIT
TROUBLESHOOTING
(CONT).
Make
sure
MASTER
switch
is
OFF
before
repairing
electrical
com-
ponents. Failure to observe this warning could result in injury to
personnel.
Disconnect lead 415 (1) from input side of circuit breaker (2). Place red
Step 3.
probe
in
lead
415.
Ground
black
probe.
Set
MASTER
switch
ON.
If
multimeter indicates about 24 volts, go to step 4. If multimeter indicates no
voltage, repair lead 415 between dome light connector and circuit breaker,
refer to page 2-66. Set MASTER switch OFF. Connect lead.