TM
9-2350-238-20-2
2-10.
ELECTRICAL
CIRCUIT
TROUBLESHOOTING
(CONT).
Step 3. Remove vehicle equipment stowage box for access to rectifier (1), refer to
rectifier. Place red probe in lead 480. Ground black probe. Set MASTER
switch ON. Set LEVEL WIND switch ON. Press sensing switch of in-
operative traversing circuit to close. If multimeter indicates about 24 volts,
go to step 4. If multimeter indicates no voltage, go to step 6. Set MASTER
switch OFF. Set LEVEL WIND switch OFF. Connect lead.
Make
sure
MASTER
switch
is
OFF
before
repairing
electrical
com-
ponents. Failure to observe this warning could result in injury to
personnel.
Step 4 .
Disconnect
connector
(1)
from
directional
control
valve
(2)
of
in-
operative traversing circuit. Place red probe in socket A (3) (lead 480).
Ground black probe. Set MASTER switch ON. Set LEVEL WIND switch ON.
Press sensing switch of inoperative traversing circuit to close. If multimeter
indicates about 24 volts, go to step 5. If multimeter indicates no voltage,
repair lead 480 between solenoid pressure relief valve and rectifier, refer to
nect connector.