TM 9-2350-238-20-1
2-179. MAINTENANCE OF HEATER INSTALLATION KIT--AIR INTAKE BLOWER,
FUEL FILTER HEATERS, AND CONNECTING HARNESS; AND POWER PLANT
COMPARTMENT BRANCHED WIRING HARNESS (CONT).
REMOVAL (CONT)
9 Tag and disconnect plug connector (13)
2 Tag and disconnect plug connector (1)
from blower assembly (14), and remove
from bulkhead disconnect to circuit
power plant compartment branched wiring
breakers and electrical components
harness (15) from hull.
branched wiring harness at the wall of the
driver's compartment.
10 If damaged, remove marker bands (16)
from power plant compartment branched
3 Tag and disconnect two shell connectors
wiring harness (15).
(2) from line connections on two fuel filter
heaters (3).
11 Remove Iockwire (17), six screws (18),
and six Iockwashers (19) from blower
4 Tag and disconnect two shell connectors
assembly (14). Remove blower assembly
(4) from line connections.
from hull.
5 Tag and disconnect shell connector (5)
NOTE
from engine coolant heater control box (6).
Steps 12 and 13 are written for one
fuel filter heater but apply to both fuel
6 Tag and disconnect shell connector (7)
filter heaters.
from electrical fuel pump (8).
12 Remove screw (20) and disconnect ground
7 Remove screw (9) and disconnect cable
lead (21) on fuel filter heater (3).
terminal (10) from ground.
13 If damaged, remove lacing cord (22) and
8 Tag and disconnect shell connector (11)
fuel heater filter (3) from fuel filter (23).
from line connection on blower assembly
electrical solenoid (12).
2-1026
|