TM 9-2350-238-20-1
2-179. MAINTENANCE OF HEATER INSTALLATION KIT--AIR INTAKE BLOWER,
FUEL FILTER HEATERS, AND CONNECTING HARNESS; AND POWER PLANT
COMPARTMENT BRANCHED WIRING HARNESS.
This task covers:
a. Removal
d.
Reassembly
e.
Installation
b. Disassembly
c. Inspection/Repair
INITIAL SETUP
Tools and Sspecial Tools
Plier wire twister (item 30, appx G)
Materials/parts
Electrical wire (figure D-2, appx D)
Electrical wire (figure D-2 appx D)
Lacing cord (figure D-16 appx D)
Lockwasher (6)
Lockwire (item 23, apx C)
Marker band (6)
References
TM 9-350-238-24P-1
Equipment conditions
2640 Batteries disconnected
General Safety Insructions
Failure to remove or disconnect batteries before removing or installing any electrical
wiring harness or lead may result in injury or damaged equipment.
Failure to remove or disconnect batteries before removing or installing any electrical
wiring harness or lead may result in injury or damaged equipment.
1 Wiring harness and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. Remove only the hardware which secures the wiring harness or lead
being removed.