2-122. MAINTENANCE OF AIR CLEANER BLOWER RELAY TO BULKHEAD
DISCONNECT BRANCHED WIRING HARNESS (CONT).
Failure to remove or disconnect batteries before removing or installing any electrical
wiring harness or lead may result in injury or damaged equipment.
Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
1
clips, ground screws, etc. Remove only the hardware which secures the wiring harness or lead
which is being removed.
Disconnect plug connector (1) from receptacle connector (2).
2
Remove four screws (3), four washers (4), and receptacle connector (2) from bulkhead.
3
Disconnect plug connector (5) from air cleaner blower relay (6).
4
Remove screw (7) and cable terminal (8) from bulkhead.
5
2-740
|