TM 9-2350-238-20-1
6 Tag and disconnect shell connector (9) from disconnect to forward air cleaner blower motor
electrical lead (10).
7 Tag and disconnect shell connector (11) from line connection.
driver's compartment.
For disassembly of wiring harness plug connector and receptacle connector, refer to general mainte-
nance, page 2-371.
1 Inspect for broken, damaged, or missing parts.
2 If damaged or missing, replace marker bands. Etch or stamp lead number on new band.
5 Repair is by replacement of authorized parts (TM 9-2350-238-24P-1).
For reassembly of wiring harness plug connector and receptacle connector, refer to general mainte-
nance, page 2-371.
Install air cleaner blower relay to bulkhead disconnect branched wiring harness (12) in driver's
1
compartment.
2
Untag and connect shell connector (11) to line connection.
Untag and connect shell connector (9) to disconnect to forward air cleaner blower motor
3
electrical lead (10).
4
Install cable terminal (8) and screw (7) on bulkhead.
Connect plug connector (5) to air cleaner blower relay (6).
5
Install receptacle connector (2), four washers (4), and four screws (3) on bulkhead.
6
7
Connect plug connector (1) to receptacle connector (2).
Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
8
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-741
|