TM 9-2350-238-20-1
2-97. MAINTENANCE OF BULKHEAD TO BULKHEAD GENERATOR CIRCUIT
ELECTRICAL LEAD.
This task covers:
a. Removal
d. Reassembly
b. Disassembly
e. Installation
c. Inspection/Repair
INITIAL SETUP
Driver's compartment aft cowl
2-928
Materials/Parts
removed
Electrical wire (figure D-2, appx D)
Gasket
General Safety Instructions
References
TM 9-2350-238-24P-1
Failure to remove or disconnect
Equipment Conditions
batteries before removing or installing
2-840 Batteries disconnected
any electrical wiring harness or lead
2-952 Driver's seat removed
may result in injury or damaged
2-928 Driver's compartment forward cowl
equipment.
removed
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
1
Wiring harnesses and leads are secured
to the hull and components with loop
clamps, straps, clips, ground screws, etc.
Remove only the hardware which secures
the wiring harness or lead being removed.
Tag and disconnect plug connector (1)
2
from voltage regulator.
Remove four screws (2) and four washers
3
(3), and tag and disconnect receptacle
connector (4) from front bulkhead recep-
tacle.
If damaged, remove gasket (5) from receptacle connector (4).
4
Remove bulkhead to bulkhead generator circuit electrical lead (6) from hull through driver's
5
compartment.
2-672
|