2-68. MAINTENANCE OF VOLTAGE REGULATOR AND RELATED PARTS (CONT).
1 Inspect for broken, damaged, or missing parts.
2 If voltage regulator is broken, damaged, or missing, repair is by replacement of next higher
assembly.
3 Repair is by replacement of authorized parts (TM 9-2350-238-24P-1) which do not meet
inspection  criteria.
1 Install two regulator mounting brackets (1) on voltage regulator (2) and secure with four
washers (3) and four screws (4).
2 Install voltage regulator (2) with attached mounting brackets, and secure with four flat washers
(5), assembled washer bolt (6), and three assembled washer bolts (7).
3 Install new Iockwasher (8), electrical grounding lead (9), new Iockwasher (8), and assembled
washer screw (10) on voltage regulator (2). Secure new Iockwasher (11), electrical grounding
lead (9), new Iockwasher (11), and hexagon head capscrew (12) to ground.
4 Connect two electrical connectors (13) to voltage regulator (2).