TM 9-2350-238-20-1
2-68. MAINTENANCE OF VOLTAGE REGULATOR AND RELATED PARTS.
This task covers:
a. Removal/Disassembly
c. Reassembly/Installation
b. Inspection/Repair
INITIAL SETUP
Materials/Parts
General Safety Instructions
Lockwasher (2)
Lockwasher (2)
References
Failure to remove or disconnect
TM 9-2350-238-24P-1
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
Equipment Conditions
2-923 CO2 cylinder access cover
equipment.
removed
2-640 Batteries disconnected
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
1
Disconnect two electrical connectors (1)
from voltage regulator (2).
2
Remove assembled washer screw (3), two
Iockwashers (4), hexagon head capscrew
(5), two Iockwashers (6), and electrical
grounding lead (7).
3
Remove three assembled washer bolts
(8), assembled washer bolt (9), and four
flat washers (10) from two regulator
mounting brackets (11 ).
Remove voltage regulator (2) with
4
attached mounting brackets.
5
Remove four screws (12), four washers
(13), and two regulator mounting brackets
(11) from voltage regulator (2).
2-557
|