TM 9-2350-238-20-1
2-67. MAINTENANCE OF GENERATOR AND COOLING AIR INTAKE SYSTEM (CONT).
INSTALLATION (CONT)
9
Install new preformed packing (23). Install six key head bolts (24), six flat washers (25), and six
new self-locking nuts (26).
Attach generator (27) and mechanical housing (28).
10
If removed, install screw (29), flat washer (30), and new self-locking nut (31) to mechanical
11
housing (28).
NOTE
If the hardware in step 11 was not removed during removal procedure, tighten self-
Iocking nut (31).
12
Install new gasket (32).
Lower generator (27) and mechanical housing (28) straight down onto generator drive (33) to
13
engage shaft.
14
Install six flat washers (34), six hexagon head capscrews (35), and new Iockwire (36) (item 27,
15
Install preformed hose (37) on air intake (38) of generator (27) and generator intake duct elbow
(16) and secure with two hose clamps (39).
16
Untag and connect four electrical leads (40) to generator (27).
2-556
|