2-54. MAINTENANCE OF AIR BOX HEATER INSTALLATION AND AIR BOX HEATER
ASSEMBLY (CONT).
REASSEMBLY (CONT)
5 Using gap gages, adjust wire (7) to fuel
spark igniter (6) to obtain air gap of 0.080
in. (0.203 cm).
1
Install elbows (1 and 2) on solenoid valve (3). Tighten securely.
2
Install solenoid valve (3), two new Iockwashers (4), and two machine screws (5) to angle
bracket (6). Tighten securely.
Install wiring harness (7).
3
4
Install wiring harness receptacle connector (8), four machine screws (9), four new Iockwashers
(10), and four hexagon plain nuts (11) on angle bracket (6).
Connect wiring harness plug connector (12) to solenoid valve (3).
5