TM 9-2350-238-20-1
1 Inspect for broken, missing, or damaged parts.
Dry cleaning solvent is toxic and flammable. Wear protective goggles and gloves
q
and use only in well-ventilated areas. Avoid contact with skin, eyes, and clothes.
Don't breathe vapors. Do not use near open flames or excessive heat. If you
become dizzy while using dry cleaning solvent, get medical aid. If contact is
made with eyes, wash your eyes with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi. Use only with
q
effective chip guarding and personal protective equipment (goggles or shield,
gloves, etc.).
2 Clean outside surface of pump with dry cleaning solvent. Dry with compressed air.
3 Clean air heater body and fuel injector nozzle with dry cleaning solvent. Dry with compressed
air.
4 Clean outside surface of ignition coil with dry cleaning solvent. Dry with compressed air.
6 For further repair, test, or adjustment, notify direct support maintenance.
7 Repair is by replacement of authorized parts (TM 9-2815-202-24P) which do not meet the
inspection criteria.
1
Install two pipe straight adapters (1 and 2)
into air heater body (3).
2
Install adapter (4) into pipe straight
adapter (1).
3
Install fuel injection nozzle (5) into air
heater body (3).
4
Screw fuel spark igniter (6) into air heater
body (3).
2-491
|