2-17. TYPICAL MALE-TYPE PANEL MOUNTING RECEPTACLE CONNECTOR (CONT).
REASSEMBLY
1
Strip cable insulation equal to depth of
solder wells of pin contacts (1).
2
Slide nut (2) onto cable (3).
Slide grommet (4) over cable leads (5).
3
Insert cable leads (5) into solder wells of
4
pin contacts (1) and solder.
Push insert (6) into shell assembly (7)
5
from rear until seated. Groove (8) in
insert (6) must be aligned with guide in
shell assembly (7) to ensure proper fit.
Push pin contacts (1) into insert (6) from
6
rear until seated.
Push grommet (4) down cable leads (5) and over solder wells of pin contacts (1).
7
8
Screw nut (2) onto shell assembly (7).
2-18. TYPICAL FEMALE-TYPE PLUG CONNECTOR.
DISASSEMBLY
1
Unscrew nut (1) from shell assembly (2)
and slide back on cable (3).
Slide grommet (4) back on cable leads (5).
2
Slide coupling (6) off shell assembly (2).
3
Drive socket contacts (7) out through rear
4
of insert (8) with pin extractor.
Push insert (8) out through rear of shell
5
assembly (2).
Unsolder cable leads (5) from socket
6
contacts (7).