2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
To access bulkhead disconnect, remove driver's seat, refer to page 2-952;
Step 5.
and remove driver's compartment aft cowl, refer to page 2-928. Disconnect
wiring harness at bulkhead disconnect. Install jumper wires to pin G and
plug socket G (lead 317) and pin D and plug socket D (lead 459). Place
red probe on pin H (lead 317A). Ground black probe. Set MASTER switch
ON. Set HYD PUMP/PTO CLUTCH switch ON. If multimeter indicates
about 24 volts, repair lead 317A between disconnect near batteries and
bulkhead disconnect. Refer to page 2-371. If multimeter indicates no
voltage, repair lead 317A between bulkhead disconnect and HYD PUMP/
PTO CLUTCH switch. Refer to page 2-371. Remove jumper wires. Set
MASTER switch OFF. Set HYD PUMP/PTO CLUTCH switch OFF. Con-
nect wiring harness.
2-288