To access disconnect near batteries, remove left C02 cylinder access cover.
Step 4.
Refer to page 2-918. Disconnect wiring harness. place red probe in socket
A (lead 317A). Ground black probe. Set MASTER switch ON. Set HYD
PUMP/PTO CLUTCH switch ON. If multimeter indicates about 24 volts,
repair lead 317A between disconnect near batteries and disconnect near
vehicular drive. Refer to page 2-371. Set MASTER switch OFF. Set HYD
PUMP/PTO CLUTCH switch OFF. Connect wiring harness.