TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 1.
To access electrical leads, open forward air cleaner blower access cover.
Disconnect lead 345 from forward air cleaner centrifugal fan. Place red
probe in lead 345 (terminal end). Ground black probe. Set MASTER and
INST switches ON. If multimeter indicates no voltage, repair lead 345 from
centrifugal fan to INST switch. Refer to page 2-371. If multimeter
indicates about 24 volts, go to step 2. Set MASTER and INST switches
OFF. Connect lead 345 to forward air cleaner centrifugal fan.
Step 2.
Disconnect lead GND from forward air cleaner centrifugal fan. Check
continuity between lead GND (pin end) and chassis ground. If no
continuity exists, repair lead GND. Refer to page 2-371. If continuity
exists, repair or replace forward air cleaner centrifugal fan. Refer to page
2-124
|