Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 12. Disconnect wiring harness at engine disconnect. Place red probe in
socket E (lead 14) of receptacle. Ground black probe. Set MASTER and
INST switches ON. Push START switch. If multimeter indicates no
voltage, repair lead 14 from engine disconnect to START switch. Refer to
page 2-371. If multimeter indicates about 24 volts, repair lead 14 from
engine disconnect to neutral position switch. Refer to page 2-371. Set
MASTER and INST switches OFF. Connect wiring harness at engine
disconnect.