TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 10. Disconnect leads 14 from START switch. Place red probe in lead 14 (pin
end). Ground black probe. Check voltage in both leads 14 (pin end). Set
MASTER and INST switches ON. If multimeter indicates no voltage in
both leads 14, repair lead 14-27 from INST switch to START switch. Refer
to page 2-371. If multimeter indicates about 24 volts in one lead 14,
connect lead 14 measuring about 24 volts to INST switch and go to step
11. Set MASTER and INST switches OFF.
2-121
|