TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 9.
Place red probe in lead 14 (pin end) of neutral position switch. Ground
black probe. Set MASTER and INST switches ON. Press START switch.
If multimeter indicates no voltage, replace neutral position switch. Refer to
between neutral position switch and starter control relay. Refer to page
neutral position switch.
2-120
|