2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 9.
Place red probe in lead 14 (pin end) of neutral position switch. Ground
black probe. Set MASTER and INST switches ON. Press START switch.
If multimeter indicates no voltage, replace neutral position switch. Refer to
page 2-562. If multimeter indicates about 24 volts, repair lead 14-14B
between neutral position switch and starter control relay. Refer to page
2-371. Set MASTER and INST switches OFF. Connect leads 14 at
neutral position switch.
2-120