4-33.
HANDBRAKE LEVER AND LINKAGE REPLACEMENT (continued).
5.
Remove two self-locking nuts (12), capscrews
(13), and spacers (14), handbrake lever (15),
and two washers (16) from frame (11). Discard
self-locking nuts.
6.
Disconnect cable assembly (3) from handbrake
lever (15).
7.
Repeat steps 1 through 6 for removal of other
handbrake lever and linkage.
b.
CLEANING AND INSPECTION
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles and gloves,
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO NOT
breathe vapors. DO NOT use near open flame or excessive heat.
1.
Clean all removed components with drycleaning solvent and rag and allow to dry.
2.
Inspect handbrake lever for bends, breaks, corrosion, and freedom of action.
Replace handbrake lever if
damaged.
3.
Inspect cable assembly for frays, cracks, distortion, corrosion, and freedom of movement in conduit. Replace
cable assembly if damaged.
4.
Inspect all mounting hardware for damage. Replace if damaged.
4-51