2320-01-318-9902 EIC:B5C, VOLUME NO. 2">

 

Click here to make tpub.com your Home Page

Page Title: Left Side Installation
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-360-20-2
d. Left Side Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing.  To avoid injury or death,
keep away from open fire and use in
well-ventilated area.  If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads.  Do
not  apply  compound  to  hose
connections.  Damage to equipment
may result.
(1) Coat threads of adapter (1) with pipe
thread sealing compound.
(2) Install adapter (1) on anchor coupling (2).
(3) Install anchor coupling (2) on battery tray
(3) with new lockwasher (4) and nut (5).
(4) Coat threads of anchor coupling (2) with
pipe thread sealing compound.
(5) Install cap (6) and coupling (7) on anchor
coupling (2).
(6) Install hose no. 2781 (8) on adapter (1).
e. Follow-On Maintenance
(1) Start engine (TM 9-2320-360-10).
(2) Build up air pressure to 120-125 psi (827-
862 kPa).
(3) Shut off engine (TM 9-2320-360-10).
(4) Check for leaks.
(5) Remove wheel chocks.
Change 1 11-199

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business