2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
11-41. ACCESSORY AIR SUPPLY COUPLING REPLACEMENT (CONT)
(4) Install anchor coupling (2) on bracket (3)
with new lockwasher (7) and nut (8).
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads. Do
not apply compound to hose
connections. Damage to equipment
may result.
(5) Coat threads of anchor coupling (2) with
pipe thread sealing compound.
(6) Install cap (9) and coupling (10) on anchor
coupling (2).
(7) Install hose no. 2782 (11) on adapter (1).
c. Left Side Removal
(1) Remove hose no. 2781 (1) from adapter
(2).
(2) Remove coupling (3) and cap (4) from
anchor coupling (5).
(3) Remove nut (6) and lockwasher (7) from
anchor coupling (5). Discard lockwasher.
(4) Remove anchor coupling (5) from battery
tray (8).
(5) Remove adapter (2) from anchor coupling
(5).
11-198 Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |