2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
7-37. MAGNETIC SWITCH REPLACEMENT
This task covers:
Removal
Follow-On Maintenance
Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Batteries disconnected (para 7-61).
Tags, Identification (Item 32, Appendix C)
Ties, Cable, Plastic (Item 34, Appendix C)
Tools and Special Tools
Tool Kit, Genl Mech (Item 54, Appendix F)
NOTE
This procedure is performed to
replace a faulty magnetic switch.
Perform proper troubleshooting
procedures to identify switch
needing replacement.
Tag and mark wires before removal.
a. R21 Relay Removal
(1) Remove 10 screws (1) and cover (2) from
electronic control box assembly (3).
NOTE
Locations of plastic cable ties should
be marked before removal.
(2) Remove plastic cable ties (4) securing
wiring.
(3) Remove nut (5) and two wires no. 1435
(6) from terminal (7).
(4) Remove nut (8) and wire no.
1055 (9)
from terminal (10).
(5) Remove nut (1 1) and wire no. 1045 (12)
from terminal (13).
(6) Remove nut (14) and wire no. 1284 (15)
from terminal (16).
Change 1 7-103
|