2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
7-37. MAGNETIC SWITCH REPLACEMENT (CONT)
(7) Remove two screws (17) and switch (18)
from electronic control box assembly (3).
b. R21 Relay Installation
(1) Install magnetic switch (1) in electronic
control box assembly (2) with two screws
(3).
(2) Install wire no.
1284 (4) and nut (5) on
terminal (6).
(3) Install wire no.
1045 (7) and nut (8) on
terminal (9).
(4) Install wire no. 1055 (10) and nut (11) on
terminal (12).
(5) Install two wires no.
1435 (13) and nut
(14 on terminal (15).
NOTE
Plastic
cable
ties
should
be
positioned in locations marked
during removal.
(6) Secure wiring with plastic cable ties (16).