2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
7-29. DDEC II ELECTRONIC CONTROL MODULE (ECM) REPLACEMENT (CONT)
NOTE
ECM wiring harnesses are designed
to be installed in only one location.
(9) Connect two ECM wiring harness connectors
(22) to ECM (2) and tighten screws (23).
(10) Connect three ECM wiring harnesses (24) to
ECM (2).
(11) Install exhaust tube (25) on turbocharger (26)
and exhaust manifold (27) with two new clamps
(28).
(12) Install two new locknuts (29) on clamps (28).
(13) Install two fuel lines (30) on fitting (31).
e. Follow-On Maintenance
(1) Connect batteries (para 7-61).
(2) Install air intake hose (para 4-4).
(3) Clear historical codes, mode 40 (para 2-13).