d. Installation
NOTE
Right injector wire harness should be
located under ECM bracket.
(1) Position ECM (1) and ECM bracket (2) on
thermostat housing (3).
(2) Position turbo bo ost sensor bracket (4) on ECM
bracket (2) with washer (5), new lockwasher (6),
and screw (7). Do not tighten screw.
(3) Position washer (8), new lockwasher (9), and
screw (10) on ECM bracket (2). Do not tighten
screw.
(4) Position clip (11), washer (12), lockwasher (13),
and screw (14) on ECM bracket (2). Do not
tighten screw.
(5) Position clip (15), washer (16), new lockwasher
(17), and screw (18) on ECM bracket (2). Do
not tighten screw.
(6) Position washer (19), new lockwasher (20), and
screw (21) on ECM bracket (2). Do not tighten
screw.
CAUTION
Screws connecting bracket to blower
must be tightened first to prevent
damage to housing.
(7) Tighten two screws (7 and 14) to 120-156 lb-in.
(13.6-17.7 Nm).
(8) Tighten three screws (10, 18, and 21) to 30-35
Ib-ft (41-47 Nm).
Change 1 7-83
|