TM 9-2320-285-24-2
3-17. TRANSMISSION MAINTENANCE (CONT)
e. Modulator Assembly (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (cont)
4
b. Cable (13)
Install
Twist housing (15) slightly
(cont)
and push cable until large
groove in cable hub aligns
with setscrew (12) hole
c. Setscrew (12)
Install
Tighten to 20-25 pounds inch
d. Thimble (11)
Position
In spring (10)
e. Cable (13) core
Retract
Pull at free end of cable
f. Thimble (11)
Install
Compress thimble and spring,
and spring
align thimble with cable
(10)
core, and release spring
g. Lever (8)
Position
In retainer
h. Lever (8) and
Install
Rotate lever and retainer
retainer (9)inward about cable
core through 90 degrees
i. Pin (7)
Install
Push into lever (8) and bore
in housing (15)
j. Gasket (6) and
Position
On housing (15)
cover (5)
k. Five capscrews
Install
Tighten to 35-40 pounds inch
(3) and locktorque
washers (4)
CAUTION
Tapered end of plunger (2) must be inserted first in following step.
l. Plunger (2)
Install
Push tapered end first into
housing (15)
m. Retaining ring
Install
Use retaining ring pliers
(1)
3-124
|